Furuno Atlantic (AOR-E), (AOR-W), Pacific (POR), and Indian (IOR) Oceans Procedures
************************************** IMPORTANT **************************************
- It is necessary to setup an address for the AMVER/SEAS message in the Standard C software. The SETUP
procedure provided below is a one-time process to be completed on initial installation.
- The TRANSMISSION instructions provided below are to be followed each time a message is transmitted.
- These instructions may vary slightly, depending on the software version and hardware.
********************************************************************************************
NOTE: Furuno first started installing the *FELCON 11* model hardware in the middle 90's for their
version of the INMARSAT "C" to work with the GMDSS. This model could not generate a Binary
message to be used with our AMVER/SEAS software.
The Furuno company has updated their hardware to the *FELCOM 12*. This new hardware will allow
an AMVER/SEAS Binary message to be transmitted on their INMARSAT "C"
SETUP PROCEDURE
- At the FURUNO Main Menu, Press F8 (SETUP). The SETUP WINDOW menu comes up on
the screen.
- Select NO.9 (CONFIGURATION) and Press <ENTER>. Select NO.1 (STATION LIST) and
press <ENTER>. Arrow down to a blank file number at the end of the list and Press <ENTER>.
- A window appears asking for: Use <ENTER> when line is highlighted to type in information and
press to accept typed in data. Use arrow keys to get to next line.
- Station Name: Enter---AMVER/SEAS
- Arrow down to DESTINATION TYPE: Select SPEC
- Arrow down to STATION ID: Enter in the word SEAS. Leave the Prefix and Country
Code Blank.
- Arrow down to REMARKS: Enter AMVER/SEAS,/B> and press <ENTER>.
- Press ESC until you return to the FURUNO MAIN MENU.
- Insert the diskette with the BINARY message that was generated with the AMVER/SEAS
program.
- Press F3 (TRANSMIT). Select NO. 1 (TRANSMIT MSG) and Press <ENTER>. The
Transmit Message window appears.
- Arrow DOWN to MESSAGE FILE and Press <ENTER>. This will allow you to see the
files stored on the diskette. Select the APPROPRIATE FILE message and Press
<ENTER>.
- Arrow DOWN to STATION NAME and Press <ENTER>. Select STATION
AMVER/SEAS and Press <ENTER>.
- Arrow DOWN to CES/LES ID and Press <ENTER>. Select the proper LES/CES and
Press <ENTER>. AOR (W) Southbury 001, AOR (E) Southbury 101, POR Santa Paula
201 and IOR Eik (Oslo) 304.
- Arrow DOWN to OPTION and Press <ENTER>. Arrow down to CONFIRMATION
and select OFF and Press <ENTER>. Arrow down to CODE and Press <ENTER>. Select
the word DATA and Press <ENTER>. (Ensure DATA is selected, because the
AMVER/SEAS message is sent as a BINARY message.)
- Press . Arrow DOWN to TRANSMIT and Press <ENTER>. A small SEND
START window appears and SELECT YES and Press <ENTER>. The message is now
being sent through the satellite.
- To see the Status of the Message being sent Press F6 (LOGS).
NOTE: The following are the FILE NAME for each particular message.
--Meteorological Observation MET.BIN
--Sail Plan SP.BIN
--Arrival Report FR.BIN
--Deviation Report DR.BIN
--Administrative Report ADMIN.BIN
|